Must 2KVA Hybrid Offgrid Inverter 24V 60A designed for efficient and reliable solar power utilization. With a 24V input and a built-in 80A charge controller, this inverter ensures seamless energy conversion and management. Ideal for off-grid applications, it supports both solar and battery power, providing a versatile solution for powering various electrical appliances.
Must 2KVA Hybrid Offgrid Inverter 24V 60A Key Features
- Hybrid Off-grid Design: Seamlessly integrates solar power with battery backup for uninterrupted energy supply.
- Advanced MPPT Technology: The built-in Must 2KVA Hybrid Offgrid Inverter 24V 60A optimizes solar energy harvesting for enhanced efficiency.
- High PV Voltage Support: Handles a maximum PV voltage of 145VDC, making it compatible with a wide range of solar panels.
- Pure Sine Wave Output: Generates clean and stable power, ensuring the safe operation of sensitive electronic devices.
- Efficient Energy Conversion: High efficiency with minimal standby power consumption, maximizing energy utilization.
- Comprehensive LCD Display: Smart LCD provides real-time information on working modes, charge current, and voltage.
- Built-in Protections: Safeguards against overload, short circuit, overvoltage, and other electrical issues for increased durability.
- Wide Battery Compatibility: Accommodates various battery types and configurations for flexibility.
Must 2KVA Hybrid Offgrid Inverter 24V 60A

Must 2KVA Hybrid Offgrid Inverter 24V 60A Technical Specifications
| MODEL | PV30-1K VPM | PV30-1.5K VPM | PV30-2K VPM | PV30-3K VPM | ||||
| Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | |
| INVERTER OUTPUT | ||||||||
| Rated Power | 1000VA | 1500VA | 2000VA | 3000VA | ||||
| Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | ||||
| Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | ||||
| Waveform | Pure sine wave / same as input (bypass mode) | |||||||
| Nominal Output Voltage RMS | 110V /115V / 120V / 220V / 230V / 240VAC (±10% RMS) | |||||||
| Output Frequency | 50Hz / 60Hz ±0.3Hz | |||||||
| Inverter Efficiency (Peak) | >88% | |||||||
| Line Mode Efficiency | >95% | |||||||
| Power Factor | 0.7 | |||||||
| Typical Transfer Time | 10ms(max) | |||||||
| Overload | 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07) | |||||||
| AC INPUT | ||||||||
| Voltage | 230VAC | |||||||
| Selectable Voltage Range | 75~135VAC; 155~265VAC (For personal computers) | |||||||
| Frequency Range | 50Hz / 60Hz(Auto sensing) 40~80Hz | |||||||
| BATTERY | ||||||||
| Minimum Start Voltage | (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
| Low Battery Alarm | (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
| Low Battery Cut Off | 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
| High Voltage Alarm | (12~14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
| High Battery Voltage Recover | (12~14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
| Idle Consumption-Search Mode | Load ≤50±20W(120V)/100±20W(220V) | |||||||
| CHARGER | ||||||||
| Output Voltage | Depends on battery type | |||||||
| Charge AC Input Breaker Rating | 120V | 1~2K/30A | 3K/40A | |||||
| 230V | 1~3K/30A | |||||||
| Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode) | |||||||
| Maximum Charge Current | 30A | 20A | 45A | 25A | 60A | 30A | 40A | |
| BYPASS & PROTECTION | ||||||||
| Input Voltage Waveform | Sine wave (grid or generator) | |||||||
| Nominal Input Frequency | 50Hz or 60Hz | |||||||
| Overload Protection (SMPS Load) | Circuit breaker | |||||||
| Output Short Circuit Protection | Circuit breaker | |||||||
| AC Input Breaker | 1-3K/30A | |||||||
| SOLAR CHARGER | ||||||||
| Maximum PV Array Power | 1000W | 2000W | 1000W | 2000W | 1000W | 2000W | 2000W | |
| Maximum PV Charge Current | 60A | |||||||
| DC Voltage | 12V / 24V auto work | |||||||
| MPPT Range @ Operating Voltage | 12V: 16~75VDC; 24V: 32-100VDC | |||||||
| Maximum PV Array Open Circuit Voltage | 12V:75VDC; 24V:100VDC | |||||||
| Standby Power Consumption | <2W | |||||||
| MECHANICAL SPECIFICATIONS | ||||||||
| Mounting | Wall Mount | |||||||
| Dimensions (W*H*D) | 303*493*200mm | |||||||
| Package Dimensions (W*H*D) | 615*400*319mm | |||||||
| N.W (kg) | / | |||||||
| G.W (kg) | / | |||||||
| OTHER | ||||||||
| Operation Temperature Range | 0°C to 40°C | |||||||
| Storage Temperature | -15°C to 60°C | |||||||
| Audible Noise | 60dB MAX | |||||||
| Display | LED+LCD | |||||||
| Standard Warranty | 1 year | |||||||
Buy Must 2KVA Hybrid Offgrid Inverter 24V 60A at the Best Price from SolarShop Africa
Checkout: MUST