GoodWe GW 10K-ET 10 Kw 3 – Phase Hybrid Ongrid Solar Inverter
- High Power Generation: Offers high power generation capability for maximum energy harvest.
- Smart Load Control: Enables flexible applications through intelligent load control.
- 100% Unbalanced Output: Ensures consistent, balanced output for improved system efficiency.
- Reliable and Safe: Prioritizes system reliability and safety for peace of mind.
- Peak Shaving Technology: Effectively balances power demand and grid power, reducing grid dependency.
- Dry Contact Functionality: Inverter includes dry contact feature for flexible activation of external loads like heat pumps, optimizing energy consumption.
Smart load control
<10ms UPS-level switching
In-built Type II SPD on DC side
IP66 ingress protection
GoodWe GW 10K-ET 10 Kilowatts Three Phase Hybrid Specifications
Battery Input Data | GW5K-ET | GW6.5K-ET | GW8K-ET | GW10K-ET | |
Battery Type | Li-Ion | ||||
Nominal Battery Voltage (V) | 500 | ||||
Battery Voltage Range (V) | 180 ~ 600 | ||||
Start-up Voltage (V) | 180 | ||||
Number of Battery Input | 1 | ||||
Max. Continuous Charging Current (A) | 25 | ||||
Max. Continuous Discharging Current (A) | 25 | ||||
Max. Charging Power (W) | 7500 | 8450 | 9600 | 10000 | |
Max. Discharging Power (W) | 7500 | 8450 | 9600 | 10000 | |
PV String Input Data | |||||
Max. Input Voltage (V)*1 | 1000 | ||||
MPPT Operating Voltage Range (V)*2 | 200 ~ 850 | ||||
Start-up Voltage (V) | 180 | ||||
Nominal Input Voltage (V) | 620 | ||||
Max. Input Current per MPPT (A) | 12.5 | 12.5 | 12.5 | 12.5 | |
Max. Short Circuit Current per MPPT (A) | 15.2 | ||||
Number of MPP Trackers | 2 | ||||
Number of Strings per MPPT | 1 | ||||
AC Output Data (On-grid) | |||||
Nominal Output Power (W) | 5000 | 6500 | 8000 | 10000 | |
Nominal Apparent Power Output to Utility Grid (VA) | 5000 | 6500 | 8000 | 10000 | |
Max. Apparent Power Output to Utility Grid (VA)*2*4 | 5500 | 7150 | 8800 | 11000 | |
Max. Apparent Power from Utility Grid (VA) | 10000 | 13000 | 15000 | 15000 | |
Nominal Output Voltage (V) | 400 / 380, 3L / N / PE | ||||
Output Voltage Range (V) | 0 ~ 300 | ||||
Nominal AC Grid Frequency (Hz) | 50 / 60 | ||||
AC Grid Frequency Range (Hz) | 45 ~ 65 | ||||
Max. AC Current Output to Utility Grid (A) | 8.5 | 10.8 | 13.5 | 16.5 | |
Max. AC Current From Utility Grid (A) | 15.2 | 19.7 | 22.7 | 22.7 | |
Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||
Max. Total Harmonic Distortion | <3% | ||||
AC Output Data (Back-up) | |||||
Back-up Nominal Apparent Power (VA) | 5000 | 6500 | 8000 | 10000 | |
Max. Output Apparent Power without grid (VA)*3 | 5000 (10000@60sec) | 6500 (13000@ 60sec) | 8000 (16000@60sec) | 10000 (16500@60sec) | |
Max. Output Apparent Power with grid (VA) | 5000 | 6500 | 8000 | 10000 | |
Max. Output Current (A) | 8.5 | 10.8 | 13.5 | 16.5 | |
Nominal Output Voltage (V) | 400 / 380 | ||||
Nominal Output Frequency (Hz) | 50 / 60 | ||||
Output THDv (@Linear Load) | <3% | ||||
Efficiency | |||||
Max. Efficiency | 98.00% | 98.00% | 98.20% | 98.20% | |
European Efficiency | 97.20% | 97.20% | 97.50% | 97.50% | |
Max. Battery to AC Efficiency | 97.50% | 97.50% | 97.50% | 97.50% | |
Protection | |||||
PV Insulation Resistance Detection | Integrated | ||||
Residual Current Monitoring | Integrated | ||||
PV Reverse Polarity Protection | Integrated | ||||
Anti-islanding Protection | Integrated | ||||
AC Overcurrent Protection | Integrated | ||||
AC Short Circuit Protection | Integrated | ||||
AC Overvoltage Protection | Integrated | ||||
DC Switch | Integrated | ||||
DC Surge Protection | Type II | ||||
AC Surge Protection | Type III | ||||
Remote Shutdown | Integrated | ||||
General Data | |||||
Operating Temperature Range (°C) | -35 ~ +60 | ||||
Relative Humidity | 0 ~ 95% | ||||
Max. Operating Altitude (m) | 4000 | ||||
Cooling Method | Natural Convection | ||||
User Interface | LED, APP | ||||
Communication with BMS*5 | RS485, CAN | ||||
Communication with Meter | RS485 | ||||
Communication with Portal | WiFi | ||||
Weight (kg) | 24 | ||||
Dimension (W × H × D mm) | 415 × 516 × 180 | ||||
Topology | Non-isolated | ||||
Self-consumption at Night (W)*6 | <15 | ||||
Ingress Protection Rating | IP66 | ||||
Mounting Method | Wall Mounted |
GoodWe GW 10K-ET Solar Inverter Smart Control for Smart Energy
Take smart load control to customize the power generation to accommodate to your load consumption needs. Thanks to the integrated export power limit, ET PLUS+ Series can adapt to any power limit imposed by the local energy provider. Enjoy the smart home with smart energy control.
Smart load control
Power export limit
Peak shaving
GoodWe GW 10K-ET Solar Inverter Flexible & Adaptable Applications
Battery ready option
100% unbalanced output
Forced battery charging
GoodWe GW 10K-ET Solar Inverter High Generation and Optimized Consumption
- High Power Generation: Offers high power generation capability for maximum energy harvest.
- Smart Load Control: Enables flexible applications through intelligent load control.
- 100% Unbalanced Output: Ensures consistent, balanced output for improved system efficiency.
- Reliable and Safe: Prioritizes system reliability and safety for peace of mind.
- Peak Shaving Technology: Effectively balances power demand and grid power, reducing grid dependency.
- Dry Contact Functionality: Inverter includes dry contact feature for flexible activation of external loads like heat pumps, optimizing energy consumption.